Home > Laboratory Animal > Ferret Isolator

Ferret Isolator

Ferret Isolator

Applied in Biosafety Level 3(BSL-3) and above laboratories, specifically designed for the rearing, experimentation, and other operations of laboratory ferrets, fulfilling both biosafety and animal experimentation requirements.

Multiple housing densities available with single or double chamber structures

Independent control ensures no mutual interference

Parallel redundant exhaust units automatically monitor pressure loss to guarantee a negative pressure environment, featuring online fan replacement capability

Model

LH7-1D-G8-BS

LH7-1D-G6-BS

Features

Multiple housing densities available with single or double chamber structures;independent control ensures no mutual interference.Parallel redundant exhaust units automatically monitor pressure loss to guarantee a negative pressure environment,featuring online fan replacement capability.

Configured with multi-stage exhaust filtration (mesh,primary,and high-efficiency filters)to provide a safe and effective environmental guarantee.

Terminal exhaust equipped with H14 HEPA filters(99.995%MPPS efficiency per EN1822), featuring automatic scan leak detection,efficiency leak testing, in-situ disinfection, and Bag-In-Bag-Out(BIBO) replacement.

Front operating side features viewing windows with gloves and multi-point mechanical compression sealing for stable biosafety assurance.

The front face adopts an ergonomic tilted design for ease of operation.

Rigid chamber structure with rounded corners, free of burrs, sharp edges, and cleaning dead zones; chamber leakage rate is less than 0.25%Vol/hr at -250 Pa.

Each chamber is equipped with an independent transfer chamber, with options for UV, pulsed xenon light, or atomization disinfection; CDCV(Cycle Development and Cycle Verification) services and comprehensive, reliable SOPs for material transfer are available.

Reserved VH2O2 interfaces for external vaporized hydrogen peroxide generators or optional built-in integrated VH2O2 systems.

Modular design with flexible configurations; the chamber and control cabinet can be integrated or placed separately, making it user-friendly for space-constrained scenarios.

Real-time monitoring of micro-environmental parameters including differential pressure,temperature, humidity, and ammonia concentration.

Built-in lighting system for operational convenience and ferret well-being.

Specifications

Model: LH7-1D-G6-BS Model: LH7-1D-G8-BS
Overall Dimensions: L2700×W800×H1890mm Overall Dimensions: L2040×W920×H2200mm
Chamber Dimensions: L1500×W800×H800mm Chamber Dimensions: L1600×W920×H900mm
Number of Chambers: 2, arranged vertically Number of Chambers: 1
Operation Method: Single-sided operation, equipped with 3 sets of integrated sleeves on the operating face Operation Method: Double-sided operation, equipped with 4 sets of integrated sleeves on each operating face
Sterile Path: Mechanical compression sealing, double-door interlocking; Optional disinfection methods: UV, pulsed xenon light, or atomized spray Sterile Path: Mechanical compression sealing, double-door interlocking; Optional disinfection methods: UV, pulsed xenon light, or atomized spray
Waste Path: / Waste Path: RTP Beta Container
Sealed Door: Tempered glass viewing window, mechanical sealing Sealed Door: Tempered glass viewing window, mechanical sealing
Pressure Control: Adjustable from (-150) to 150 Pa; differential pressure between the interior and exterior of the chamber ≥ 50 Pa Pressure Control: Adjustable from (-150) to 150 Pa; differential pressure between the interior and exterior of the chamber ≥ 50 Pa
Airflow Control: Air changes ≥ 20 times/h Airflow Control: Air changes ≥ 20 times/h
Caging: Built-in ferret cage rack inside the chamber Caging: Built-in ferret cage rack inside the chamber

Compliance

The relevant regulations and industry standards are as follows:

GB14925-2023 Laboratory Animal-Requirements for Environment and Housing Facilities

GB50346-2011 Architectural and Technical Code for Biosafety Laboratories

GB50447-2008 Architectural and Technical Code for Laboratory Animal Facilities

RBT010-2019 General Requirements for the Evaluation of Barrier and Isolation Devices for Laboratory Animals

RBT019-2019 Guidelines for Performance and Environmental Parameter Verification  Procedures for Laboratory Animal Facilities

RBT199-2015 Technical Specifications for Biosafety Performance Evaluation of Laboratory Equipment

Applications

Send Inquiry

Article

News
Corporate

05/02/2026

Tailin MD500 Microbial Detection Analyzer Validated by Provincial Authorities for Rapid Testing

News
Corporate

29/01/2026

Tailin Bioengineering 2025 Annual Review and Awards Ceremony

News
Insights

29/01/2026

High-Throughput Asymmetric PES Membrane for Biopharma | Filtailin® XA

News
Insights

14/01/2026

Filtailin® MCE 0.45μm Membrane: Empowering Bio-pharmaceutical R&D and Production

Reserve Event

Event:

Date and time:

30 June - 2 July 2026 09:00am - 18:00pm

Add:

KoelnMesse Halls 7+8, Cologne, Germany

Booth:

Hall 7, N21

Reservation Form

Reserve Event

Event:

Date and time:

16-18 June 2026 09:00am - 18:00pm

Add:

Shanghai New International Expo Center, Shanghai, China

Booth:

N3B56

Reservation Form

Reserve Event

Event:

Date and time:

21-23 April 2026 09:00am - 17:00pm

Add:

Algiers exhibition center – SAFEX (Central Hall)

Booth:

B04 (224)

Reservation Form