Home > Filter Integrity Testing > Filter Integrity Tester

HTY-FT224

Filter Integrity Tester

The Filter Integrity Tester FT224 is a microcomputer-based, intelligent, and highly sensitive precision analytical instrument independently developed by Tailin, specifically designed for detecting the integrity of filter elements and membranes in filtration systems.

Bubble point, forward flow

Water intrusion, pressure hold

Forward flow and bubble point combined detection

Features

  • Dust-proof & Backflow-proof Design: Can be easily cleaned to prevent liquid backflow and microbial contamination upstream of the filter.
  • Capacitive Screen Design: Upgraded 10-inch ultra-large capacitive screen with a user-friendly interface and higher resolution; ±88°viewing angle, and compatible with gloves.
  • Multiple Data Interface Configurations: Can customizable the output port, the generated data can be transmitted via Ethernet cable or WIFI.
  • Short Test Time: The bubble point test time is short, higher than the industry average level; the forward flow has high sensitivity and a wide detection range.
  • Dust-free High-Fidelity Printing Technology: Data results can be printed out quickly and efficiently and stored for a long time, with a storage period of more than 10 years.
  • Data IntegrityFully comply with GMP and 21 CFR Part 11 requirements for electronic data integrity with four levels of password authority, an audit trail function, and various forms of backup.

Specifications

Input Voltage: (100-240)VAC Test Accuracy to Forward Flow: ±4% or 0.1mL/min
Input Frequency: 50/60Hz Test Accuracy to Water Intrusion: ±4% or 0.02mL/min
Input Power: 160W Test Accuracy to Bubble Point: ±50mbar
Sensitivity to Forward Flow: 0.01mL/min Test Range to Forward Flow: (0.1-1000)mL/min
Sensitivity to Water Intrusion: 0.01mL/min Test Range to Water Intrusion: (0.01-100)mL/min
Sensitivity to Bubble Point: 1mbar Test Range to Bubble Point: (100-8000)mbar
Repeatability: ≤3% Test Range to Pressure Maintenance: (100-8000)mbar
Dimension: 27cm×46cm×35cm Sensitivity to Pressure Hold: 1mbar

Applications

  • Pharmaceutical Industry: Suitable for integrity testing of various hydrophilic and hydrophobic filters, including pleated cartridges, capsule filters, disc membranes, and filter assemblies.
  • Food & Beverage Industry: Designed for filter testing in the production of wine, mineral water, and drinking water.

Pharmaceuticals

Food & beverage

Municipal industries

Send Inquiry

Article

News
Corporate

05/02/2026

Tailin MD500 Microbial Detection Analyzer Validated by Provincial Authorities for Rapid Testing

News
Corporate

29/01/2026

Tailin Bioengineering 2025 Annual Review and Awards Ceremony

News
Insights

29/01/2026

High-Throughput Asymmetric PES Membrane for Biopharma | Filtailin® XA

News
Insights

14/01/2026

Filtailin® MCE 0.45μm Membrane: Empowering Bio-pharmaceutical R&D and Production

Reserve Event

Event:

Date and time:

30 June - 2 July 2026 09:00am - 18:00pm

Add:

KoelnMesse Halls 7+8, Cologne, Germany

Booth:

Hall 7, N21

Reservation Form

Reserve Event

Event:

Date and time:

16-18 June 2026 09:00am - 18:00pm

Add:

Shanghai New International Expo Center, Shanghai, China

Booth:

N3B56

Reservation Form

Reserve Event

Event:

Date and time:

21-23 April 2026 09:00am - 17:00pm

Add:

Algiers exhibition center – SAFEX (Central Hall)

Booth:

B04 (224)

Reservation Form