Filter Integrity Tester
Fast detection speed, high cost performance
A filter integrity tester is a testing device that verifies the integrity of filter elements such as filter cartridges and filter membranes using a non-destructive method.
Widely used in industries such as pharmaceuticals, bioengineering, and food and beverage.
Model
Features
- Versatile Testing Modes: Supports Bubble Point, Forward Flow, Water Intrusion, Combined Forward Flow & Bubble Point, and Pressure Hold, meeting diverse filter integrity verification needs.
- High Testing Efficiency: Powered by high-precision sensing technology and intelligent prediction algorithms, it delivers fast and reliable results while significantly reducing test duration.
- User-Friendly: 10-inch color touchscreen with Windows OS, one-click testing, and multitasking capability.
- Flexible Options: Optional needle or thermal printer, supports multiple communication protocols such as OPC-UA and Modbus TCP, adaptable for both online and offline use.
- Data Compliance: 4-level user access control with GMP-compliant audit trail, supports dual-level approval,e-signatures, and data encryption.
- Reliable Design: IP54 for dust and splash resistance, modular hardware architecture and redundant safety mechanisms.
Specifications
| Weight | 12kg |
| Input Voltage | (100-240)VAC |
| Input Frequency | 50/60Hz |
| Input Power | 125W |
| Fuse Blown | <5A |
| Dimensions | 420mm×330mm×265mm |
| Dperating Temperature | (5~50)℃ |
| Storage Temperature | (-10~60)℃ |
| Ambient Humidity | ≤85%RH,non-condensing |
| Test Range | (1)Forward Flow:(0.01~1000)mL/min (2)Water Intrusion:(0.01~100)mL/min (3)Bubble Point:(400~8000)mbar (4)Pressure Hold:(100~8000)mbar |
| Sensitivity | (1)Forward Flow:0.01mL/min (2)Water Intrusion:0.01mL/min (3)Bubble Point:50mbar (4)Pressure Hold:1mbar |
Compliance
EU GMP Annex 1 for the manufacture of sterile medicinal products, February 2008
GMP: The integrity of the sterilised filter should be verified before use and should be confmed immediately after use by an appropriate method such as a bubble point, diffusive flow or pressure hold test.
US FDA Guideline on Sterile Drug Products Produced by Aseptic Processing, 2004
US FDA: Integrity testing of the filter can be performed prior to process and should be routinely performed post-use.
PDA@ Technical Report 26-2008
Where the claimed purpose of the filter is to sterilize, pre and post filtration integrity tests should be performed. Steps should be taken to ensure that the downstream side of the system remains sterile when perfomming a post sterilization, pre-use integrity test.
Applications
The product can be used for:
1) Disposable filtration system PUPSIT
2) Radiopharmaceutical production
3) Pharmaceutical liquid preparation system
4) Intake pressure recovery system on freeze dryers

Pharmaceutical liquid preparation system

Radiopharmaceutical production

Disposable filtration system PUPSIT
Send Inquiry

Related Products

Filter Integrity Tester

Online Filter Integrity Tester

Water Activity Meter

Water Activity Meter
Articles

USP <1231> Revision 2027: Online TOC Monitoring and Analyzer Selection Guide

Radiopharmaceutical Manufacturing Solutions: 3 GMP Case Studies by Tailin

Microbial Testing of Compressed Gases in Pharmaceutical Manufacturing: From Regulatory Requirements to Method Selection