    Ferret Isolator

    Designed for the rearing, experimentation, and other operations of laboratory ferrets

    Applied in Biosafety Level 3(BSL-3) and above laboratories, specifically designed for the rearing, experimentation, and other operations of laboratory ferrets, fulfilling both biosafety and animal experimentation requirements.

    01
    Multiple housing densities available with single or double chamber structures
    02
    Independent control ensures no mutual interference
    03
    Parallel redundant exhaust units automatically monitor pressure loss to guarantee a negative pressure environment, featuring online fan replacement capability

    Model

    Ferret Isolator
    LH7-1D-G6-BS
    Ferret Isolator
    LH7-1D-G8-BS

    Features

    Multiple housing densities available with single or double chamber structures;independent control ensures no mutual interference.Parallel redundant exhaust units automatically monitor pressure loss to guarantee a negative pressure environment,featuring online fan replacement capability.

    Configured with multi-stage exhaust filtration (mesh,primary,and high-efficiency filters)to provide a safe and effective environmental guarantee.

    Terminal exhaust equipped with H14 HEPA filters(99.995%MPPS efficiency per EN1822), featuring automatic scan leak detection,efficiency leak testing, in-situ disinfection, and Bag-In-Bag-Out(BIBO) replacement.

    Front operating side features viewing windows with gloves and multi-point mechanical compression sealing for stable biosafety assurance.

    The front face adopts an ergonomic tilted design for ease of operation.

    Rigid chamber structure with rounded corners, free of burrs, sharp edges, and cleaning dead zones; chamber leakage rate is less than 0.25%Vol/hr at -250 Pa.

    Each chamber is equipped with an independent transfer chamber, with options for UV, pulsed xenon light, or atomization disinfection; CDCV(Cycle Development and Cycle Verification) services and comprehensive, reliable SOPs for material transfer are available.

    Reserved VH2O2 interfaces for external vaporized hydrogen peroxide generators or optional built-in integrated VH2O2 systems.

    Modular design with flexible configurations; the chamber and control cabinet can be integrated or placed separately, making it user-friendly for space-constrained scenarios.

    Real-time monitoring of micro-environmental parameters including differential pressure,temperature, humidity, and ammonia concentration.

    Built-in lighting system for operational convenience and ferret well-being.

    Specifications

    Model: LH7-1D-G6-BSModel: LH7-1D-G8-BS
    Overall Dimensions: L2700×W800×H1890mmOverall Dimensions: L2040×W920×H2200mm
    Chamber Dimensions: L1500×W800×H800mmChamber Dimensions: L1600×W920×H900mm
    Number of Chambers: 2, arranged verticallyNumber of Chambers: 1
    Operation Method: Single-sided operation, equipped with 3 sets of integrated sleeves on the operating faceOperation Method: Double-sided operation, equipped with 4 sets of integrated sleeves on each operating face
    Transfer Channel: Sterile transfer port, docks with sterile transfer trolley via dunk tank; mechanical sealing for chamber interior and exteriorTransfer Channel: Sterile transfer port, docks with sterile transfer trolley for waste transfer channel; isolates and transfers out waste
    Sterile Path: Mechanical compression sealing, double-door interlocking; Optional disinfection methods: UV, pulsed xenon light, or atomized spraySterile Path: Mechanical compression sealing, double-door interlocking; Optional disinfection methods: UV, pulsed xenon light, or atomized spray
    Waste Path: /Waste Path: RTP Beta Container
    Sealed Door: Tempered glass viewing window, mechanical sealingSealed Door: Tempered glass viewing window, mechanical sealing
    Pressure Control: Adjustable from (-150) to 150 Pa; differential pressure between the interior and exterior of the chamber ≥ 50 PaPressure Control: Adjustable from (-150) to 150 Pa; differential pressure between the interior and exterior of the chamber ≥ 50 Pa
    Airflow Control: Air changes ≥ 20 times/hAirflow Control: Air changes ≥ 20 times/h
    Caging: Built-in ferret cage rack inside the chamberCaging: Built-in ferret cage rack inside the chamber

    Compliance

    The relevant regulations and industry standards are as follows:

    GB14925-2023 Laboratory Animal-Requirements for Environment and Housing Facilities

    GB50346-2011 Architectural and Technical Code for Biosafety Laboratories

    GB50447-2008 Architectural and Technical Code for Laboratory Animal Facilities

    RBT010-2019 General Requirements for the Evaluation of Barrier and Isolation Devices for Laboratory Animals

    RBT019-2019 Guidelines for Performance and Environmental Parameter Verification  Procedures for Laboratory Animal Facilities

    RBT199-2015 Technical Specifications for Biosafety Performance Evaluation of Laboratory Equipment