Opens in a new tab
  • BIT-L01

    CCIT – Bacterial Ingress Tester

    Designed to perform testing of and verify the container closure integrity

    The CCIT- Bacterial Ingress Tester is critical to maintaining the sterility of drugs intended to be sterile. GMP specifies that the integrity of packaging & containers shall be validated for the pharmaceutical products.

    Tailin Container Closure Integrity Tester BIT-L01: specifically designed to perform testing of and verify the container closure integrity. By setting different pressures, it can verify the microbial barrier performance of specific packaging containers and sealing quality.

    01
    Compact design, saves space
    02
    Safe and reliable use process, no microbial leakage
    03
    Built-in gas source components, no external gas source required

    Model

    Features

    • Test samples of different specifications of various products
    • Easy to operate, easy to plug and unplug the tank connector
    • Compact design, saves space
    • The test tank is made of colorless, transparent, high-strength material, resistant to high temperature and high pressure, and easy to observe the test results
    • Safe and reliable use process, no microbial leakage
    • Built-in gas source components, no external gas source required
    • Equipped with an equipment self-test function to ensure safe use
    • Real-time printing function of basic test information and test process data

    Specifications

    Pressure Adjustment Range: -80 ~ +100KPaTest Vessel Sterilization: Autoclave sterilization
    Keep Time: 0-999minUser Authority: 3-level user authority management
    Pressure Adjustment Accuracy: ±0.5KPaAlarm:1.Test vessel overpressure/under-pressure alarm
    2.Self-diagnostic failure alarm
    3.Test vessel pressure deviation alarm
    Pressure Detection Accuracy:±0.25KPaMonitoring Parameters:Time,Pressure
    Pressure Reading Resolution:0.1KPaRecipe Edit &Recall:Support
    Gauge Pressure Error. ±0.5KPaData Export:Support data export in the form of reports
    Infusion Flow:(0~1500)mL/minData Printing:Dot matrix micro printer
    Recipe Storage Capacity:No less than 100Power:≤500W

    Applications

    • Evaluation of the consistency of injections — Package Integrity Test
    • Qualification of the capping & sealing process
    • Verification of the validity of physical inspection methods
    • Establishing a relationship between orifice size and microbial barrier performance
    • Drug stability study and validation
    • Microbial challenge testing on conditions for transport and storage of sterile packages

    Pharmaceutical liquid preparation system

    Radiopharmaceutical production

    Disposable filtration system PUPSIT

    Send Inquiry