BIT-L01
CCIT – Bacterial Ingress Tester
Designed to perform testing of and verify the container closure integrity
The CCIT- Bacterial Ingress Tester is critical to maintaining the sterility of drugs intended to be sterile. GMP specifies that the integrity of packaging & containers shall be validated for the pharmaceutical products.
Tailin Container Closure Integrity Tester BIT-L01: specifically designed to perform testing of and verify the container closure integrity. By setting different pressures, it can verify the microbial barrier performance of specific packaging containers and sealing quality.
01
Compact design, saves space
02
Safe and reliable use process, no microbial leakage
03
Built-in gas source components, no external gas source required
Model
Features
- Test samples of different specifications of various products
- Easy to operate, easy to plug and unplug the tank connector
- Compact design, saves space
- The test tank is made of colorless, transparent, high-strength material, resistant to high temperature and high pressure, and easy to observe the test results
- Safe and reliable use process, no microbial leakage
- Built-in gas source components, no external gas source required
- Equipped with an equipment self-test function to ensure safe use
- Real-time printing function of basic test information and test process data
Specifications
| Pressure Adjustment Range: -80 ~ +100KPa | Test Vessel Sterilization: Autoclave sterilization |
| Keep Time: 0-999min | User Authority: 3-level user authority management |
| Pressure Adjustment Accuracy: ±0.5KPa | Alarm:1.Test vessel overpressure/under-pressure alarm |
| 2.Self-diagnostic failure alarm | |
| 3.Test vessel pressure deviation alarm | |
| Pressure Detection Accuracy:±0.25KPa | Monitoring Parameters:Time,Pressure |
| Pressure Reading Resolution:0.1KPa | Recipe Edit &Recall:Support |
| Gauge Pressure Error. ±0.5KPa | Data Export:Support data export in the form of reports |
| Infusion Flow:(0~1500)mL/min | Data Printing:Dot matrix micro printer |
| Recipe Storage Capacity:No less than 100 | Power:≤500W |
Applications
- Evaluation of the consistency of injections — Package Integrity Test
- Qualification of the capping & sealing process
- Verification of the validity of physical inspection methods
- Establishing a relationship between orifice size and microbial barrier performance
- Drug stability study and validation
- Microbial challenge testing on conditions for transport and storage of sterile packages

Pharmaceutical liquid preparation system

Radiopharmaceutical production

Disposable filtration system PUPSIT
Send Inquiry

Related Products
HTY-LT100P

CCIT – Vacuum/Pressure Decay Leak Tester
Designed to test the seal integrity of pharmaceutical packaging systems
BIT-L01S

CCIT – Bacterial Ingress Tester
External air source
HTY-FT223 Pro

Filter Integrity Tester
Designed for detecting the integrity of filter elements and membranes in filtration systems
HTY-FT100

Filter Integrity Tester
Fast detection speed, high cost performance
Articles

News
|
25.11.2026
USP <1231> Revision 2027: Online TOC Monitoring and Analyzer Selection Guide

News
|
17.11.2026
Radiopharmaceutical Manufacturing Solutions: 3 GMP Case Studies by Tailin

News
|
21.10.2026
Microbial Testing of Compressed Gases in Pharmaceutical Manufacturing: From Regulatory Requirements to Method Selection

News
|
18.09.2026