TOC Analyzer
UV + Persulfate Oxidation + Membrane Conductivity Detection
The Total Organic Carbon (TOC) Analyzer HTY-GM2000/3000 uses UV, Persulfate Oxidation, and Membrane Conductivity Detection to measure organic carbon in water, ideal for detecting the TOC in purified water, Water for Injection (WFI), and cleaning validation.
Model


Features
- Excellent Reproducibility, Extra-long Calibration Stabilization Period: UV+persulfate oxidation, membrane conductometric detection. The sensor is highly sensitive and provides stable performance.
- Low Maintenance Cost: Disassembly-free design requires no professional tools for installation, operation and maintenance.
- Professional Algorithm: Dynamic detection technology combined with professional algorithms to ensure good data repeatability.
- SQL Database: Powerful software and SQL database to improve efficiency.
- Provide 3Q: IQ / OQ / PQ.
- Data Integrity: Fully comply with GMP and 21 CFR Part 11 requirements for electronic data integrity with four levels of password authority, an audit trail function, and various forms of backup.
Specifications
| HTY-GM2000 | HTY-GM3000 |
| Test Range: 0.10ppb-20.00ppm | Test Range: 0.10ppb-30.00pm |
| TIC: (0.0001-5.000)mg/L | TIC: (0.0001-5.000)mg/L |
| Repeatability: ≤3% | Repeatability: ≤2% |
| Indication Accuracy: ±5% | Indication Accuracy: ±3% |
| Analysis Time: 2min | Analysis Time: 2.5min |
| UV Wavelength: 185nm&254nm | UV Wavelength: 185nm&254nm |
| Sample Temperature: (1-95)℃ | Sample Temperature: (1-95)℃ |
| R.H:≤85%RH | R.H:≤85%RH |
| Power Supply:(100-240)VAC | Power Supply:(100-240)VAC |
| Rated Power:100W | Rated Power:100W |
| Power Supply Frequency:50HZ | Power Supply Frequency:50HZ |
| Weight:30kg | Weight:30kg |
| Dimensions:480mm×300mm×540mm | Dimensions:480mm×300mm×540mm |
Applications
Applied in testing purified water, water for injection & cleaning validation (TOC method) in the pharmaceutical industry, and test sewage and drinking water in the environmental protection and municipal sectors.

Pharmaceuticals

Food & beverage

Municipal industries
FAQ
What are the main application areas of the GM2000/3000?
This product can be used in the detection of pharmaceutical and drinking water, verification of cleanliness in the pharmaceutical industry, control of TOC (Total Organic Carbon) in the biochemical industry, and detection of sewage and wastewater in environmental monitoring.
What detection principle does the GM2000/3000 use?
The product utilizes a thin-film conductivity detection principle. It oxidizes organic matter in samples into carbon dioxide through chemical reagents and measures the conductivity change to calculate the total organic carbon concentration.
Is the GM2000/3000 fully automated? What are its automated functions?
Yes, this product features a fully automated design. It can automatically complete sample collection, reagent addition, sample acidification and oxidation, reaction signal acquisition and measurement, and waste liquid discharge. Additionally, the instrument has a pipeline cleaning function to effectively avoid sample cross-contamination.
How does it meet strict data integrity requirements?
The system is fully compliant with GMP/GLP and 21 CFR Part 11, featuring electronic signatures, a comprehensive audit trail, and multi-level user access control.

Send Inquiry

Related Products

TOC Analyzer

TOC Analyzer

TOC Analyzer

TOC Analyzer
Articles

Radiopharmaceutical Manufacturing Solutions: 3 GMP Case Studies by Tailin

Microbial Testing of Compressed Gases in Pharmaceutical Manufacturing: From Regulatory Requirements to Method Selection

Containment Isolator for Crushing and Weighing: The Ultimate GMP Solution for API Production