Home > VH2O2 Sterilization System > Hydrogen Peroxide Gas Concentration Analyzer

HK Series

Hydrogen Peroxide Gas Concentration Analyzer

The Hydrogen Peroxide Gas Concentration Analyzer employs TDLAS technology (Tunable Diode Laser Absorption Spectroscopy), utilizing the principle that specific wavelengths of light are absorbed by specific gases. This enables real-time monitoring of hydrogen peroxide and water vapor concentrations, while simultaneously calculating relative saturation and dew point temperature. By establishing a relationship with the D-value, the sterilization efficacy can be assessed through hydrogen peroxide and water vapor concentrations, allowing for the analysis and evaluation of VH2O2 and optimization of process parameters.

Utilizes TDLAS gas analysis method

Short response time

Strong adaptability to working conditions

Model

In-situ  HTY-HK100D

In-situ  HTY-HK200

Bypass HTY-HK200D

Features

  • Short Response Time: Real-time monitoring of gas concentration, with the fastest response time of 0.1s per data point.
  • Wide Detection Range: Hydrogen peroxide gas detection range (1-7000) ppm.
  • Strong Adaptability to Working Conditions: Can be used in high pressure, normal pressure, vacuum environment, high temperature up to 80℃, and takes up little space.
  • D Value Development: D value development models can be established based on the output dew point temperature and relative saturation.
  • High Accuracy: The linear error of hydrogen peroxide and water gas concentration is less than 5%.
  • Good Stability: Stable data and good repeatability ensure data reliability throughout the sterilization process.

Specifications

H2O2 Range: (1-7000) ppm (range adjustable according to actual application H2O2 Repeatability: ≤±5%
H2O Range: (1500-30000) ppm (range adjustable according to actual application) H2O Repeatability: ≤±5%
H2O2 Accuracy: ≤±5% H2O Accuracy: ≤±5%
Ambient Pressure: (0-0.2) MPa Certification: CE
Weight: HK200 (7.4kg), HK200D (10.74kg), HK100D (5.2kg) Detection Medium Temperature: (-20-80)°C
Ambient Temperature & Humidity: (0-40)°C, (0-85)% RH Detection Time: 1s (fastest 0.1s)
Signal Output: Supports RS485 digital signal output, 4-20mA analog signal output

Applications

Applicable in hydrogen peroxide sterilization scenarios such as pharmaceutical VH2O2 sterilization and low-temperature plasma sterilizers.
Applicable in hydrogen peroxide sterilization process monitoring for aseptic filling lines in food and beverage.

Tailin Bioengineering

Pharmaceutical and Biotech Production

Tailin Bioengineering

Medical and Laboratory Facilities

Tailin Bioengineering

Public Health Industry

Send Inquiry

Article

VH2O2 Sterilization
News
Insights

24/03/2026

VH2O2 Sterilization Validation: Synergistic Roles of BIs and CIs

Hydrogen Peroxide Gas Concentration Analyzer
News
Cases

20/03/2026

Application of VH2O2 Gas Concentration Analyzer in Aseptic Packaging Lines

PVDF Blotting Membrane
News
Products

06/03/2026

New Launch: Tailin Immutailin™ PVDF Blotting Membrane

HPAPI Containment
News
Insights

25/02/2026

HPAPI Containment: Balancing Safety & Efficiency in OEB 5 Era

Reserve Event

Event:

Date and time:

30 June - 2 July 2026 09:00am - 18:00pm

Add:

KoelnMesse Halls 7+8, Cologne, Germany

Booth:

Hall 7, N21

Reservation Form

Reserve Event

Event:

Date and time:

16-18 June 2026 09:00am - 18:00pm

Add:

Shanghai New International Expo Center, Shanghai, China

Booth:

N3B56

Reservation Form

Reserve Event

Event:

Date and time:

21-23 April 2026 09:00am - 17:00pm

Add:

Algiers exhibition center – SAFEX (Central Hall)

Booth:

B04 (224)

Reservation Form