Home > VH2O2 Sterilization System > Hydrogen Peroxide Gas Concentration Analyzer

HK Series

Hydrogen Peroxide Gas Concentration Analyzer

Used for detecting hydrogen peroxide sterilization applications

The Hydrogen Peroxide Gas Concentration Analyzer employs TDLAS technology (Tunable Diode Laser Absorption Spectroscopy), utilizing the principle that specific wavelengths of light are absorbed by specific gases. This enables real-time monitoring of hydrogen peroxide and water vapor concentrations, while simultaneously calculating relative saturation and dew point temperature. By establishing a relationship with the D-value, the sterilization efficacy can be assessed through hydrogen peroxide and water vapor concentrations, allowing for the analysis and evaluation of VH2O2 and optimization of process parameters.

Utilizes TDLAS gas analysis method

Short response time

Strong adaptability to working conditions

Model

In-situ  HTY-HK100D

In-situ  HTY-HK200

Bypass HTY-HK200D

Features

  • Short Response Time: Real-time monitoring of gas concentration, with the fastest response time of 0.1s per data point.
  • Wide Detection Range: Hydrogen peroxide gas detection range (1-7000) ppm.
  • Strong Adaptability to Working Conditions: Can be used in high pressure, normal pressure, vacuum environment, high temperature up to 80℃, and takes up little space.
  • D Value Development: D value development models can be established based on the output dew point temperature and relative saturation.
  • High Accuracy: The linear error of hydrogen peroxide and water gas concentration is less than 5%.
  • Good Stability: Stable data and good repeatability ensure data reliability throughout the sterilization process.

Specifications

H2O2 Range: (1-7000) ppm (range adjustable according to actual application H2O2 Repeatability: ≤±5%
H2O Range: (1500-30000) ppm (range adjustable according to actual application) H2O Repeatability: ≤±5%
H2O2 Accuracy: ≤±5% H2O Accuracy: ≤±5%
Ambient Pressure: (0-0.2) MPa Certification: CE
Weight: HK200 (7.4kg), HK200D (10.74kg), HK100D (5.2kg) Detection Medium Temperature: (-20-80)°C
Ambient Temperature & Humidity: (0-40)°C, (0-85)% RH Detection Time: 1s (fastest 0.1s)
Signal Output: Supports RS485 digital signal output, 4-20mA analog signal output

Applications

Applicable in hydrogen peroxide sterilization scenarios such as pharmaceutical VH2O2 sterilization and low-temperature plasma sterilizers.
Applicable in hydrogen peroxide sterilization process monitoring for aseptic filling lines in food and beverage.

Tailin Bioengineering

Pharmaceutical and Biotech Production

Tailin Bioengineering

Medical and Laboratory Facilities

Tailin Bioengineering

Public Health Industry

Send Inquiry

Article

OEB 5 containment isolator
News
Products

26/06/2026

OEB 5 Containment Isolator for High-Potency Weighing and Sampling: Balancing Safety, Accuracy, and Compliance

NC Membrane
News
Products

12/06/2026

Why Proper Storage of NC Membranes Matters More Than You Think

MCE membrane
News
Insights

22/05/2026

Tailin and Zhejiang University Advance CNF-Based Nanofiltration Membranes Utilizing MCE Membrane Support

VHP Sterilization
News
Cases

20/05/2026

How VH2O2/VHP Sterilization Supports for BSL-3 Laboratory Large-Space Decontamination

Reserve Event

Event:

Date and time:

6 - 8 October 2026 10:00am - 18:30pm

Add:

Fiera Milano, Italy

Booth:

9C65

Reservation Form

Reserve Event

Event:

Date and time:

1 - 3 September 2026 10:00am - 18:00pm

Add:

Egypt International Exhibition Center

Booth:

H4D36

Reservation Form

Reserve Event

Event:

Date and time:

20 - 21 August 2026 9:00am - 19:00pm

Add:

Suntec Singapore

Booth:

315

Reservation Form