Home > Glove Integrity Tester (GIT) > Glove Integrity Tester

GIT-MINI02

Glove Integrity Tester

The GIT-MINI02 is designed to test the integrity of isolator/RABS system sleeves, gloves, or integrated gloves. It features an intelligent, all-in-one control and display system, and can be connected to test ports compatible with isolator access points.

It operates in positive pressure mode, requiring no manual intervention from the operator. The display screen automatically shows the test results throughout the process, allowing for direct assessment of the gloves’ sealing integrity.

In-situ testing, no sleeve/glove removal

Battery-powered design, no external power required

Built-in air pump, no external air source required

Features

  • Good human-computer interaction interface, easy to observe and operate.
  • Support three levels of operation authority.
  • Testing process is carried out online without removing the sleeve/glove structure.
  • Portable structure design, easy to use.
  • Complying with ISO14644-7 requirements.

Specifications

Inflation Pressure: 500Pa~2500Pa Test Time: 3-8min
Smallest Detectable Hole: 100μm Continuous Working Time: ≥4 hours
Net Weight: ≈2.5Kgs Battery: 12V Lithium battery
Pressure Display Resolution: 0.1Pa Charging Time: 4h
Input Pressure: >0.2MPa Dimensions: 260mmx280mmx125mm
Storage Data: 10,000 groups Detection Port Dia: Φ255mm or customized

Compliance

ISO14644-7 Annex E.5

“The pressure decay tests described are only a few of many tests that can be used for glove testing and are intended to illustrate glove leak test procedures.”

 

EU GMP Annex 1 (2022) 4.21

“For isolators, leak testing of the glove system should be performed using a methodology demonstrated to be suitable for the task and criticality. The testing should be performed at defined intervals. ”

“For RABS… Gloves should be visually examined with each use, and integrity testing should be performed at periodic intervals.”

 

FDA Guidance for Industry: Sterile Drug Products Produced by Aseptic Processing (2004) Appendix 1

“…Physical integrity tests should also be performed routinely. A breach in glove integrity can be of serious consequence. …”

Applications

Tailin Bioengineering

Pharmaceutical and Biotechnology Aseptic Production

Tailin Bioengineering

Food Industry Safety Control

Tailin Bioengineering

High-Risk Industrial Protection

Send Inquiry

Article

VH2O2 Sterilization
News
Insights

24/03/2026

VH2O2 Sterilization Validation: Synergistic Roles of BIs and CIs

Hydrogen Peroxide Gas Concentration Analyzer
News
Cases

20/03/2026

Application of VH2O2 Gas Concentration Analyzer in Aseptic Packaging Lines

PVDF Blotting Membrane
News
Products

06/03/2026

New Launch: Tailin Immutailin™ PVDF Blotting Membrane

HPAPI Containment
News
Insights

25/02/2026

HPAPI Containment: Balancing Safety & Efficiency in OEB 5 Era

Reserve Event

Event:

Date and time:

30 June - 2 July 2026 09:00am - 18:00pm

Add:

KoelnMesse Halls 7+8, Cologne, Germany

Booth:

Hall 7, N21

Reservation Form

Reserve Event

Event:

Date and time:

16-18 June 2026 09:00am - 18:00pm

Add:

Shanghai New International Expo Center, Shanghai, China

Booth:

N3B56

Reservation Form

Reserve Event

Event:

Date and time:

21-23 April 2026 09:00am - 17:00pm

Add:

Algiers exhibition center – SAFEX (Central Hall)

Booth:

B04 (224)

Reservation Form