HTY-CT1000B

TOC Analyzer

High Temperature Combustion Oxidation Method + Non-Dispersive Infra-Red (NDIR) detection

Tailin TOC analyzer HTY-CT1000B uses the method of high-temperature combustion oxidation, where the sample undergoes catalytic oxidation in an oxygen-rich environment at temperatures ranging from 680℃ to 1200℃. The generated CO2 is then introduced into a non-dispersive infrared gas detector (NDIR) via carrier gas for detection.

Solid Combustion Module

Wide Test Concentration Range

Intelligent Design

Features

  • Solid Combustion Module: An Optional solid combustion module can test solid samples such as soil and degradable plastics.
  • Manual/Automatic Injection: Manual injection and automatic injection for choice, follow the GMP computerized system verification.
  • Combustion Furnace Has Multiple Protections: Independent circuit overheating protection: When overheating, it can automatically cut off heating to protect product safety.
  • With an Eight-channel Rotary Valve: Realize automatic quantitative operation of sample acid, oxidant, sample, purge and waste discharge. 
  • Electronic Dual Refrigeration Module& Membrane Dehydration Tech: Ensure the dehydration efficiency of the entire system to protect the NDIR detector.
  • Data Integrity: Fully comply with GMP and 21 CFR Part 11 requirements for electronic data integrity with four levels of password authority, an audit trail function, and various forms of backup.

Specifications

Detection Range:(0-30000.0)mg/L(Diluted state) Test Items:TC/IC/TOC/NPOC
Ambient Temperature:(5-40)℃ Resolution:0.001mg/L
Relative Humidity:(1-85)%RH Repeatability Standard Deviation(RSD):≤3%
Power Supply:(220±10%)VAC,50/60Hz Reliable grounding is required TC Indication Error:±0.1%FS or±5%(Whichever is bigger)
Power:1200W when the electric furnace heats up IC Indication Error:±0.1%FS or±4%(Whichever is bigger)
Detection Method:Non-dispersive infrared absorption method(NDIR) Linear.R²≥99.9%
Combustion Furnace Temperature Room temperature~1000℃(limit 1200℃) Injection Volume Liquid(0.1-1)mL,Solid 10mg-1g
Testing Time:3min Weight:55kg
Dimensions:620x450x495mm Sample Temperature:(1-95)℃

Applications

Can detect all kinds of sewage, garbage permeate, sludge,etc. in the environmental protection industry; it can monitor all kinds of degradable materials, composition, etc.

Tailin Bioengineering

Pharmaceuticals

Tailin Bioengineering

Food & beverage

Tailin Bioengineering

Municipal industries

Send Inquiry

Article

Tailin Family Open Day-1
News
Corporate

27/08/2026

Tailin Family Open Day: Where Family Meets Science

SS6-121R Rapid Biological Indicator for Steam Sterilization
News
Products

21/08/2026

Rapid Biological Indicator: Enabling 3-Hour Steam Sterilization Monitoring

TOC Analyzer
News
Products

14/08/2026

Ph. Eur. 12.3 Update: How TOC Analyzers Are Advancing Pharmaceutical Water Quality Control

VHP Generator
News
Products

29/07/2026

Mini VH2O2/VHP Generator Delivers Powerful Biosafety Cabinets Decontamination

Reserve Event

Event:

Date and time:

24 - 26 November 2026 10:00am - 18:00pm

Add:

IEML, Delhi

Booth:

5A11

Reservation Form

Reserve Event

Event:

Date and time:

6 - 8 October 2026 10:00am - 18:30pm

Add:

Fiera Milano, Italy

Booth:

9C65

Reservation Form

Reserve Event

Event:

Date and time:

1 - 3 September 2026 10:00am - 18:00pm

Add:

Egypt International Exhibition Center

Booth:

H4D36

Reservation Form