Home > Containment Isolator for API&HPAPI > Containment Isolator

Isolator for Feeding

Containment Isolator

Tailin Containment Isolator is designed to protect operators during operations such as weighing, dispensing, drying, pressing, and filling of highly potent and toxic products. It is mainly applied in pharmaceuticals, cosmetics, bioproduct research, and physico-chemical laboratory studies. The system generates turbulent airflow through a high-pressure exhaust fan, maintaining negative pressure inside the working area. This design effectively prevents cross-contamination between internal and external environments, ensuring the safety of both personnel and the surrounding environment.

Continuous liner system

Siemens touch screen

H14 PUSH-PUSH HEPA

Features

  • Fully explosion-proof design which meets the EXd II BT4 requirements.
  • The chamber is made of pure titanium for greater corrosion resistance.
  • Flexible and easy to move.

Specifications

Fresh Air Supply Volume: ≥100m³/h Net Weight : 500kg
Public Utilities: Clean compressed air 0.6Mpa≤P≤0.8Mpa Power: 380V, 1.5kw
Overall Size (mm): 2105x880x2000(L*W*H) Operation Chamber Space (mm): 1800x750x800(L*W*H)
Doors: All doors adopt mechnical press sealing, the observation window is made of 12mm thickness tempered glass It is equipped with an exhaust port on the isolator top, and the piping is connected to the outdoor.

Applications

Used for feeding operations in highly corrosive environments.

High-Potency Laboratory

Weighing, dispensing, sampling, solution preparation, analysis, moisture titration, infrared scanning, and other operations.

Active Pharmaceutical Ingredients (APIs)

Centrifugation, filtration, drying, mixing, milling, weighing, dispensing, and related processes.

Solid Dosage Forms

Granulation, drying, mixing, tablet compression, coating, and other solid formulation processes.

Send Inquiry

Article

News
Insights

25/02/2026

HPAPI Containment: Balancing Safety & Efficiency in OEB 5 Era

News
Corporate

05/02/2026

Tailin MD500 Microbial Detection Analyzer Validated by Provincial Authorities for Rapid Testing

News
Insights

29/01/2026

High-Throughput Asymmetric PES Membrane for Biopharma | Filtailin® XA

News
Insights

14/01/2026

Filtailin® MCE 0.45μm Membrane: Empowering Bio-pharmaceutical R&D and Production

Reserve Event

Event:

Date and time:

30 June - 2 July 2026 09:00am - 18:00pm

Add:

KoelnMesse Halls 7+8, Cologne, Germany

Booth:

Hall 7, N21

Reservation Form

Reserve Event

Event:

Date and time:

16-18 June 2026 09:00am - 18:00pm

Add:

Shanghai New International Expo Center, Shanghai, China

Booth:

N3B56

Reservation Form

Reserve Event

Event:

Date and time:

21-23 April 2026 09:00am - 17:00pm

Add:

Algiers exhibition center – SAFEX (Central Hall)

Booth:

B04 (224)

Reservation Form