Home > TOC Analyzer > TOC Analyzer

HTY-CT1000B

TOC Analyzer

Tailin TOC analyzer HTY-CT1000B uses the method of high-temperature combustion oxidation, where the sample undergoes catalytic oxidation in an oxygen-rich environment at temperatures ranging from 680℃ to 1200℃. The generated CO2 is then introduced into a non-dispersive infrared gas detector (NDIR) via carrier gas for detection.

Solid Combustion Module

Wide Test Concentration Range

Intelligent Design

Features

  • Solid Combustion Module: An Optional solid combustion module can test solid samples such as soil and degradable plastics.
  • Manual/Automatic Injection: Manual injection and automatic injection for choice, follow the GMP computerized system verification.
  • Combustion Furnace Has Multiple Protections: Independent circuit overheating protection: When overheating, it can automatically cut off heating to protect product safety.
  • With an Eight-channel Rotary Valve: Realize automatic quantitative operation of sample acid, oxidant, sample, purge and waste discharge. 
  • Electronic Dual Refrigeration Module& Membrane Dehydration Tech: Ensure the dehydration efficiency of the entire system to protect the NDIR detector.
  • Data Integrity: Fully comply with GMP and 21 CFR Part 11 requirements for electronic data integrity with four levels of password authority, an audit trail function, and various forms of backup.

Specifications

Detection Range:(0-30000.0)mg/L(Diluted state) Test Items:TC/IC/TOC/NPOC
Ambient Temperature:(5-40)℃ Resolution:0.001mg/L
Relative Humidity:(1-85)%RH Repeatability Standard Deviation(RSD):≤3%
Power Supply:(220±10%)VAC,50/60Hz Reliable grounding is required TC Indication Error:±0.1%FS or±5%(Whichever is bigger)
Power:1200W when the electric furnace heats up IC Indication Error:±0.1%FS or±4%(Whichever is bigger)
Detection Method:Non-dispersive infrared absorption method(NDIR) Linear.R²≥99.9%
Combustion Furnace Temperature Room temperature~1000℃(limit 1200℃) Injection Volume Liquid(0.1-1)mL,Solid 10mg-1g
Testing Time:3min Weight:55kg
Dimensions:62x45x49.5cm Sample Temperature:(1-95)℃

Applications

Can detect all kinds of sewage, garbage permeate, sludge,etc. in the environmental protection industry; it can monitor all kinds of degradable materials, composition, etc.

Tailin Bioengineering

Pharmaceuticals

Tailin Bioengineering

Food & beverage

Tailin Bioengineering

Municipal industries

Send Inquiry

Article

VH2O2 Sterilization
News
Insights

24/03/2026

VH2O2 Sterilization Validation: Synergistic Roles of BIs and CIs

Hydrogen Peroxide Gas Concentration Analyzer
News
Cases

20/03/2026

Application of VH2O2 Gas Concentration Analyzer in Aseptic Packaging Lines

PVDF Blotting Membrane
News
Products

06/03/2026

New Launch: Tailin Immutailin™ PVDF Blotting Membrane

HPAPI Containment
News
Insights

25/02/2026

HPAPI Containment: Balancing Safety & Efficiency in OEB 5 Era

Reserve Event

Event:

Date and time:

30 June - 2 July 2026 09:00am - 18:00pm

Add:

KoelnMesse Halls 7+8, Cologne, Germany

Booth:

Hall 7, N21

Reservation Form

Reserve Event

Event:

Date and time:

16-18 June 2026 09:00am - 18:00pm

Add:

Shanghai New International Expo Center, Shanghai, China

Booth:

N3B56

Reservation Form

Reserve Event

Event:

Date and time:

21-23 April 2026 09:00am - 17:00pm

Add:

Algiers exhibition center – SAFEX (Central Hall)

Booth:

B04 (224)

Reservation Form