Opens in a new tab
  • GIT-WLAN02

    Glove Integrity Tester

    Used to leak test gloves installed on isolators or RABS

    Glove Leak Tester for Pharmaceutical Isolators

    In aseptic manufacturing environments, isolator gloves serve as one of the most critical contamination barriers between operators and sterile products. Even minor glove leakage may compromise sterility assurance, increase contamination risks, and impact compliance with EU GMP Annex 1 requirements.

    The GIT-WLAN02 Wireless Glove Integrity Tester is designed for automated in-situ glove leak testing in isolators and RABS systems. Utilizing advanced pressure decay testing technology, the system delivers reliable, repeatable, and traceable glove integrity verification without removing gloves from the barrier system.

    Equipped with RFID glove identification, wireless communication, and integrated data management capabilities, the GIT-WLAN02 helps pharmaceutical manufacturers simplify routine glove testing while improving contamination control and audit readiness.

    The system is designed in accordance with EU GMP Annex 1, ISO 14644-7 and supports 21 CFR Part 11 compliant electronic record management for GMP-regulated manufacturing environments.

    Compared with manual visual inspection, automated glove integrity testing provides more consistent and objective leak detection, helping reduce operational risks in critical aseptic processes.

    01
    Multi-layer structure, the size could be customized (test port dia >130mm)
    02
    With built-in lithium battery, no need external power supply, the battery is easy to be charged
    03
    In-situ detecting, which can detect multiple gloves

    Model

    Features

    Contamination Control:

     

    In-Situ Glove Integrity Testing, No Removal Required

    Enables glove and sleeve testing directly on isolators and RABS systems without removal, maintaining barrier integrity and minimizing contamination risk in aseptic environments.

    Built-In Air Pump, No External Compressed Air Required

    Eliminates dependency on external compressed air systems, reducing cleanroom infrastructure exposure and minimizing contamination risk during setup and operation.

    Ultra-Fast Inflation System with Airtight Adapter

    High-speed inflation with sealed connection minimizes air leakage risk and ensures stable pressure conditions for reliable integrity testing in GMP environments.

    Compatible with RABS and Isolator Systems

    Designed for glove and sleeve integrity testing in both RABS and isolators before or after use, supporting contamination control strategies in aseptic manufacturing.

     


    Operational Efficiency:

     

    Compact and Portable Design

    Lightweight and compact structure enables easy movement between isolators and production areas, supporting flexible routine testing workflows.

    Quick Switching Test Ports

    Allows rapid switching between multiple test ports, enabling efficient multi-glove testing and reducing downtime during routine operations.

    Replaceable Battery, No Charging Downtime

    Supports continuous field operation with quick battery replacement, eliminating delays caused by charging cycles in production environments.

    Up to 8 Hours Standby Time

    Extended standby capability supports full-shift operation for routine glove integrity testing across multiple systems.

    Microcontroller-Based Control with Color LCD

    Stable microcontroller system with intuitive color LCD interface simplifies operation and reduces training requirements for cleanroom staff.

    Automatic Port Adaptation & Fast Connection System

    Enables fast setup and switching between glove interfaces, improving workflow efficiency in multi-isolator environments.

     


    Data Integrity & Compliance:

     

    RFID-Based Automatic Glove Identification

    RFID technology automatically links each glove with its test record, ensuring complete traceability and reducing manual documentation errors.

    Wireless Communication to Monitoring System

    Wireless data transmission enables centralized real-time monitoring and supports digital GMP documentation workflows.

    Upper-Level Control and Data Acquisition Software

    Centralized software platform enables data acquisition, visualization, and management for improved traceability and operational oversight.

    GMP/FDA-Compliant Design Supporting IQ/OQ/PQ

    System is designed for regulated pharmaceutical environments and supports validation activities including Installation Qualification (IQ), Operational Qualification (OQ), and Performance Qualification (PQ).

    Clean and GMP-Compliant Operation

    Designed for controlled cleanroom environments with simplified operation to reduce human error and support GMP-compliant workflows.

    Specifications

    Inflation Pressure: 500~2500PaTest Time: 3min~6min
    Pressure Display Resolution: 0.1PaSmallest Detectable Hole: 100μm
    N.W.: ≈3kgDimensions: Ф280mm×150mm
    Battery: 12V Lithium batteryPower: ≤20W
    Continuous Working Time: ≥4 hoursCommunication: WIFI

    Compliance

    ISO14644-7 Annex E.5

    “The pressure decay tests described are only a few of many tests that can be used for glove testing and are intended to illustrate glove leak test procedures.”

     

    EU GMP Annex 1 (2022) 4.21

    “For isolators, leak testing of the glove system should be performed using a methodology demonstrated to be suitable for the task and criticality. The testing should be performed at defined intervals. ”

    “For RABS… Gloves should be visually examined with each use, and integrity testing should be performed at periodic intervals.”

     

    FDA Guidance for Industry: Sterile Drug Products Produced by Aseptic Processing (2004) Appendix 1

    “…Physical integrity tests should also be performed routinely. A breach in glove integrity can be of serious consequence. …”

    Applications

    Reliable Glove Testing for Controlled Production Environments

     

    For isolators

    GIT-WLAN02 is designed for glove testing in isolator systems. Pressure decay testing helps ensure barrier integrity in sterile production environments and is suitable for routine inspections.

    For RABS

    In Restricted Access Barrier Systems (RABS), GIT-WLAN02 delivers reproducible glove integrity testing with configurable test parameters suitable for routine qualification and periodic checks.

    Pharmaceutical and Biotechnology Aseptic Production

    Food Industry Safety Control

    High-Risk Industrial Protection

    FAQ

    glove integrity teser GIT-WLAN02

    Send Inquiry