Sterile Pass Box
Turbulent flow
GMP Grade A/B Sterile Transfer Chamber for Aseptic Manufacturing
The STP Series Sterile Pass Box / Sterile Transfer Chamber achieve biological decontamination of the interior space, surfaces, and items (outer surfaces) through an integrated vaporized hydrogen peroxide (VH2O2) system. The integrated VH2O2 system is linked with the sterile pass box using SIEMENS PLC control. Communication between the sterile pass box and the VH2O2 system allows for the setting of relevant decontamination parameters, after which the system’s built-in program supports unattended automatic operation.
Model
Features
Using VH2O2 102/202 as a biological decontaminant, maintaining a low temperature and normal pressure during the decontamination process, which is efficient and environmentally friendly.
The system provides real-time monitoring of the temperature, humidity, and pressure inside the chamber.
Offering a complete 40-cycle program and on-site validation.
During the biological decontamination and exhaust phases, all air entering the chamber is filtered through an H14-grade HEPA filter to prevent contamination of materials.
The loading and unloading system features a double-door structure with pneumatic sealing, pneumatic locking, and an interlocking mechanism for the double doors during operation.
The airflow inside the chamber is turbulent, facilitating gas diffusion when handling multi-layer loads.
The loading and unloading doors are made of stainless steel frames and high-visibility tempered glass, sealed with pneumatic seals for excellent visibility.
Specifications
| Airflow: Turbulence | Cleanliness: GMP Grade A |
| Biological Decontamination Cycle Time: 150 minutes | Biological Decontamination Capability: Log reduction value≥6 |
| VH2O2 Residual Level: ≤1ppm | High-Efficiency Filter Grade: Supply air HEPA (H14), Exhaust air HEPA (H14) |
| Printing: Includes biological decontamination cycle parameter saving and printing functions | Alarm: High pressure/low pressure alarm, door open timeout alarm, door lock alarm, concentration/temperature alarm |
| Exhaust Interface: 3-inch or 4-inch sanitary interface | Hydrogen Peroxide Gas Decontamination Cycle Interface: 1.5-inch sanitary interface |
| Material of Inside Chamber: SUS316L stainless steel | |
Applications
It is widely used in microelectronics, biological laboratories, pharmaceutical factories, hospitals, and the food industry—any environment requiring air purification. It is suitable for transferring various clean and dry items in sterile production, including the outer packaging of packaging materials, instruments, raw materials, accessories, and environmental monitoring equipment that enter A and B critical areas.

Pharmaceutical Industry

Biotechnology Industry

Food and Beverage
FAQ
What is the primary function of the STP Series Sterile Pass Box for sterile transfer?
The STP Series Sterile Pass Box achieves biological decontamination of interior spaces, surfaces, and item outer surfaces using an integrated Vaporized Hydrogen Peroxide (VH2O2) system. Controlled by a Siemens PLC, it supports unattended automatic operation after parameter setup and is designed to ensure safe sterile transfer of materials between cleanrooms.
How long does the biological decontamination cycle take, and what is the residual level?
-
Cycle Time: Approximately 150 minutes.
-
Decontamination Capability: Log reduction value ≥ 6.
VH2O2 Residual Level: Controlled at ≤1 ppm post-cycle.
-
How are safety and air quality maintained during operation?
-
Airflow & Cleanliness: Features turbulent flow inside to facilitate gas diffusion when handling multi-layer loads, achieving GMP Grade A cleanliness.
-
Filtration: Both supply air and exhaust air are filtered through H14-grade HEPA filters to prevent contamination.
-
Door Interlocks & Sealing: Utilizes a double-door structure featuring pneumatic sealing, pneumatic locking, and an automatic interlocking mechanism to prevent both doors from opening simultaneously during operation.
-
What regulatory standards and validation support does the equipment provide?
The system complies with 21 CFR Part 11, includes biological decontamination cycle parameter saving and printing functions, and provides a complete 4Q qualification package with on-site validation support.
What materials can be processed in this sterile transfer chamber, and can the chamber size be customized?
The STP Series sterile transfer chamber is designed for transferring clean, dry items into GMP Grade A/B critical areas—including outer packaging materials, precision instruments, raw materials, accessories, and environmental monitoring equipment. Depending on your facility’s throughput and load dimensions, we offer standard chamber sizes (such as STP400, STP600, and STP1000) as well as customized chamber configurations with turbulent airflow to ensure uniform VH2O2 gas diffusion across multi-layer loads.
Send Inquiry

Related Products

Sterile Pass Box

Sterility Test Isolator

Sterility Test Isolator

Automatic Aseptic Filling lsolator
Articles

USP <1231> Revision 2027: Online TOC Monitoring and Analyzer Selection Guide

Radiopharmaceutical Manufacturing Solutions: 3 GMP Case Studies by Tailin

Microbial Testing of Compressed Gases in Pharmaceutical Manufacturing: From Regulatory Requirements to Method Selection