HTY-CT1000B
TOC Analyzer
High Temperature Combustion Oxidation Method + Non-Dispersive Infra-Red (NDIR) detection
Tailin TOC analyzer HTY-CT1000B uses the method of high-temperature combustion oxidation, where the sample undergoes catalytic oxidation in an oxygen-rich environment at temperatures ranging from 680℃ to 1200℃. The generated CO2 is then introduced into a non-dispersive infrared gas detector (NDIR) via carrier gas for detection.
01
Solid Combustion Module
02
Wide Test Concentration Range
03
Intelligent Design
Model
Features
- Solid Combustion Module: An Optional solid combustion module can test solid samples such as soil and degradable plastics.
- Manual/Automatic Injection: Manual injection and automatic injection for choice, follow the GMP computerized system verification.
- Combustion Furnace Has Multiple Protections: Independent circuit overheating protection: When overheating, it can automatically cut off heating to protect product safety.
- With an Eight-channel Rotary Valve: Realize automatic quantitative operation of sample acid, oxidant, sample, purge and waste discharge.
- Electronic Dual Refrigeration Module& Membrane Dehydration Tech: Ensure the dehydration efficiency of the entire system to protect the NDIR detector.
- Data Integrity: Fully comply with GMP and 21 CFR Part 11 requirements for electronic data integrity with four levels of password authority, an audit trail function, and various forms of backup.
Specifications
| Detection Range:(0-30000.0)mg/L(Diluted state) | Test Items:TC/IC/TOC/NPOC |
| Ambient Temperature:(5-40)℃ | Resolution:0.001mg/L |
| Relative Humidity:(1-85)%RH | Repeatability Standard Deviation(RSD):≤3% |
| Power Supply:(220±10%)VAC,50/60Hz Reliable grounding is required | TC Indication Error:±0.1%FS or±5%(Whichever is bigger) |
| Power:1200W when the electric furnace heats up | IC Indication Error:±0.1%FS or±4%(Whichever is bigger) |
| Detection Method:Non-dispersive infrared absorption method(NDIR) | Linear.R²≥99.9% |
| Combustion Furnace Temperature Room temperature~1000℃(limit 1200℃) | Injection Volume Liquid(0.1-1)mL,Solid 10mg-1g |
| Testing Time:3min | Weight:55kg |
| Dimensions:620x450x495mm | Sample Temperature:(1-95)℃ |
Applications
Can detect all kinds of sewage, garbage permeate, sludge,etc. in the environmental protection industry; it can monitor all kinds of degradable materials, composition, etc.

Pharmaceuticals

Food & beverage

Municipal industries
Send Inquiry

Related Products
HTY-GM2000/3000

TOC Analyzer
UV + Persulfate Oxidation + Membrane Conductivity Detection
HTY-DI1500

TOC Analyzer
Dual-Wavelength UV Oxidation + Direct Conductivity Detection
HTY-DI1500-OL

TOC Analyzer
Dual-Wavelength UV Oxidation + Direct Conductivity Detection
HTY-DC150

TOC Analyzer
Dual-Wavelength UV Oxidation + Direct Conductivity Detection
Articles

News
|
25.11.2026
USP <1231> Revision 2027: Online TOC Monitoring and Analyzer Selection Guide

News
|
17.11.2026
Radiopharmaceutical Manufacturing Solutions: 3 GMP Case Studies by Tailin

News
|
21.10.2026
Microbial Testing of Compressed Gases in Pharmaceutical Manufacturing: From Regulatory Requirements to Method Selection

News
|
18.09.2026