HTY-WOT100
TOC Analyzer
UV + Persulfate Oxidation + Non-dispersive Infra-Red (NDIR) Detection
Tailin TOC analyzer HTY-WOT100 utilizes a wet oxidation decomposition process employing ultraviolet light + persulfate. In the UV reactor, carbon-containing compounds are thoroughly oxidized by the persulfate solution under the action of ultraviolet light (UVC), converting them fully into CO2. The CO2 is then carried by a high-purity carrier gas (N2) to the NDIR detection cell, completing the CO2 detection process.
01
For Cleaning Validation
02
Injection Water Testing
03
Wide Test Concentration Range
Model
Features
- Dual Oxidation Design: Oxidation: dual wavelength UV + sodium persulfate oxidation. Detection principle: non-dispersive infrared detection.
- Wide Test Range& High Precision: Can test purified water, water for injection, drinking water, surface water and other water samples; can test various acid, alkali and salt water samples.
- Dual Sensor Configuration: It can measure TC, IC, NPOC, and TOC.
- With an Eight-channel Rotary Valve: Realize automatic quantitative operation of sample acid, oxidant, sample, purge, and waste discharge.
- Consumables Easily Replaced: The main consumables are phosphoric acid and sodium persulfate solution. Low maintenance cost, simple and convenient.
- Data Integrity: Fully comply with GMP and 21 CFR Part 11 requirements for electronic data integrity with four levels of password authority, an audit trail function, and various forms of backup.
Specifications
| Detection Range: (0-100.0)ppm | Power Supply: (100-240)VAC 50/60HZ |
| Rated Power: 300W | Sample Temperature: (1-95)℃ |
| Calibration Stability: 12 months | Repeatability: ≤3% |
| Weight: 35kg | Noise: ≤55dB |
| Indication Error: TC±5% IC±4% | Ambient Temperature: (10-40℃, (5-90)%RH, non-condensing |
| Dimensions: 550x450x530mm | |
Applications
Applied in testing purified water, water for injection & cleaning validation (TOC method) in the pharmaceutical industry, and test sewage and drinking water in the environmental protection and municipal sectors.

Pharmaceuticals

Food & beverage

Municipal industries
Send Inquiry

Related Products
HTY-GM2000/3000

TOC Analyzer
UV + Persulfate Oxidation + Membrane Conductivity Detection
HTY-DI1500

TOC Analyzer
Dual-Wavelength UV Oxidation + Direct Conductivity Detection
HTY-DI1500-OL

TOC Analyzer
Dual-Wavelength UV Oxidation + Direct Conductivity Detection
HTY-DC150

TOC Analyzer
Dual-Wavelength UV Oxidation + Direct Conductivity Detection
Articles

News
|
25.11.2026
USP <1231> Revision 2027: Online TOC Monitoring and Analyzer Selection Guide

News
|
17.11.2026
Radiopharmaceutical Manufacturing Solutions: 3 GMP Case Studies by Tailin

News
|
21.10.2026
Microbial Testing of Compressed Gases in Pharmaceutical Manufacturing: From Regulatory Requirements to Method Selection

News
|
18.09.2026